Sealant ageing tester for IGU

Used for:

Adhesion test for outer sealants and metal edge seals in IGU

 

Conforms to:

EN 1279-4


Principle of operation:

First the samples are subject to ageing conditions. Exposure to UV is  followed by exposure to temperature and moisture. After this, the samples are tested with the tensile tester.


Technical characteristics:

UV Chamber:

UV source: 300W UVA

Irradiation: 40+-5W/m2

Inner size: 56x56x56cm


Climate cabinet:

Temperature range: room temperature -20°C to +150°C, +-0.5°C

Humidity range: 20%-98%RH, +2 to -3 %RH

Inner size: 45x45x50cm