Resistance to radiation test: The purpose of this test is to determine whether the light transmittance of laminated-glass panes, glass-plastics glazing or glass glazing faced with plastics material when exposed to radiation over an extended period of time is significantly reduced thereby or whether the glazing is significantly discoloured.
ECE R43 Annex 3 paragraph 6.1 and EN 12543-4 Method B
It is an apparatus containing a radiation source of medium-pressure mercury-vapor arc lamp with a tubular quartz bulb of ozone-free type. The bulb axis is vertical. There is a circular sample rack, enabling the rotation of the glass samples around the radiation source to ensure even exposure.